Researchers Uncover Main Safety Vulnerabilities in Industrial MMS Protocol Libraries

[ad_1]

Oct 09, 2024Ravie LakshmananIndustrial Safety / Vital Infrastructure

Industrial MMS Protocol Libraries

Particulars have emerged about a number of safety vulnerabilities in two implementations of the Manufacturing Message Specification (MMS) protocol that, if efficiently exploited, might have extreme impacts in industrial environments.

“The vulnerabilities might enable an attacker to crash an industrial gadget or in some circumstances, allow distant code execution,” Claroty researchers Mashav Sapir and Vera Mens mentioned in a brand new evaluation.

MMS is an OSI utility layer messaging protocol that permits distant management and monitoring of commercial units by exchanging supervisory management info in an application-agnostic method.

Particularly, it permits for communication between clever digital units (IEDs) and supervisory management and knowledge acquisition (SCADA) programs or programmable logic controllers (PLCs).

Cybersecurity

The 5 shortcomings recognized by the operational expertise safety firm influence MZ Automation’s libIEC61850 library and Triangle MicroWorks’ TMW IEC 61850 library, and have been patched in September and October 2022 following accountable disclosure –

  • CVE-2022-2970 (CVSS rating: 10.0) – A stack-based buffer overflow vulnerability in libIEC61850 that would result in a crash or distant code execution
  • CVE-2022-2971 (CVSS rating: 8.6) – A sort confusion vulnerability in libIEC61850 that would enable an attacker to crash the server with a malicious payload
  • CVE-2022-2972 (CVSS rating: 10.0) – A stack-based buffer overflow vulnerability in libIEC61850 that would result in a crash or distant code execution
  • CVE-2022-2973 (CVSS rating: 8.6) – A null pointer deference vulnerability that would enable an attacker to crash the server
  • CVE-2022-38138 (CVSS rating:7.5) – An entry of uninitialized pointer vulnerability that permits an attacker to trigger a denial-of-service (DoS) situation

Claroty’s evaluation additionally discovered that Siemens SIPROTEC 5 IED relied on an outdated model of SISCO’s MMS-EASE stack for MMS help, which is vulnerable to a DoS situation by way of a specifically crafted packet (CVE-2015-6574, CVSS rating: 7.5).

The German firm has since up to date its firmware with an up to date model of the protocol stack as of December 2022, in accordance with an advisory launched by the U.S. Cybersecurity and Infrastructure Safety Company (CISA).

The analysis highlights the “hole between trendy expertise’s safety calls for and the outdated, hard-to-replace protocols,” Claroty mentioned, urging distributors to comply with safety pointers issued by CISA.

The disclosure comes weeks after Nozomi Networks detailed two vulnerabilities within the reference implementation of Espressif’s ESP-NOW wi-fi protocol (CVE-2024-42483 and CVE-2024-42484) that would enable replay assaults and trigger a DoS situation.

Cybersecurity

“Relying on the system being focused, this vulnerability [CVE-2024-42483] can have profound penalties,” it mentioned. “ESP-NOW is utilized in safety programs reminiscent of constructing alarms, permitting them to speak with movement sensors.”

“In such a state of affairs, an attacker might exploit this vulnerability to replay a beforehand intercepted legit ‘OFF’ command, thereby disabling a movement sensor at will.”

Alternatively, ESP-NOW’s use in distant door openers, reminiscent of computerized gates and storage doorways, could possibly be weaponized to intercept an “OPEN” command and replay it at a later time to achieve unauthorized entry to buildings.

Again in August, Nozomi Networks additionally make clear a set of unpatched 37 vulnerabilities within the OpenFlow libfluid_msg parsing library, collectively dubbed FluidFaults, that an adversary might exploit to crash Software program-Outlined Networking (SDN) functions.

“An attacker with community visibility to an OpenFlow controller/forwarder can ship a malicious OpenFlow community packet that results in a denial-of-service (DoS) assault,” the corporate mentioned.

In latest months, safety flaws have additionally been uncovered in Beckhoff Automation’s TwinCAT/BSD working system that would expose PLCs to logic tampering, DoS assaults, and even command execution with root privileges on the controller.

Discovered this text attention-grabbing? Observe us on Twitter and LinkedIn to learn extra unique content material we submit.